Civil/Commercial/Intelligent Sensors
TOP
The detection distance is 3 times as high as that of the similar color sensor.
Dual mode has the function of color + light intensity detection, so the detection is more stable and accurate.
Light point size 1.5*7mm (23mm detection distance)
The products of XAORI technology are designed and manufactured for general products of the general industry.Therefore, our products should not be used for the following applications and are not suitable for their use.However, the product can be used if the purchaser consults in advance on the use of the product in charge of its own responsibility and understands the technical specifications, grades and performance of the product, and takes the necessary safety measures. Under such circumstances, the scope of product warranty is the same as the above.
• Facilities that have serious impact on life and property, such as nuclear power plants, airports, railways, ships, mechanic device and medical equipment.
• Public utilities such as electricity, gas and water services
• Outdoor use of a similar condition or ambient
Technical specifications
Type | Cable type | ||
Model | NPN | PNP | |
S3-A20N | S3-A20P | ||
Detection distance | 18 to 28mm | ||
Power | 24V DC ± 10% pulsation P-P10% or less | ||
Current consumpiton | Power less than 850mW (power voltage is 24V, the current consumption is below 35mA). | ||
Mode switching input | Light intensity mode | Low(ON) 0 to 0.6V DC Outflow current below 0.5mA Input impedance about10kΩ | Low(OFF) 0 to 0.6V DC or open |
Color mode | High(OFF)12 to +V DC or open | High(ON) 12 to +V DC OUtflow current below 3mA Input impedance about10kΩ | |
Output | NPN open collector transistor ·Maximum inflow current 50mA ・Applied voltage 30V DC or less (between output and 0V) · Residual voltage 1.5V or less (when inflow current is 50mA) * | PNP open collector transistor ·Maximum outgoing current 50mA ・Applied voltage 30V DC or less (between output and +V) · Residual voltage 1.5V or less (when sourcing current 50mA) * | |
Output control | light intensity mode | mode Light intensity output ON | |
Color mode | Color matching ON | ||
Short circuit protection | Equipped (automatic recovery) | ||
Reaction time | Below 200μs | ||
Ambient temperature | - 10 to +55°C, no freezing, no condensation | ||
Ambient humidity | 35 to 85%RH, non-condensing | ||
Optical element | Composite LED: red/green/blue (Projection peak wavelength: 640nm/525nm/470mm) | ||
Material | Housing: PBT / Operation Panel: PC / Operation Buttons: Silicone / Lens: PC | ||
Cable | 0.2mm 4 core rubber cable standard 2m Distinction (color matching) Brown: +V Black: output Pink: mode conversion input blue: 0V | ||
Weight | About110g |
Name of each component
Wiring
Note: when the pink line break(OFF) is for the color mode, when the pink line is connection(ON) is for the light intensity mode
Size diagram
* specified measurement conditions: ambient temperature +23℃.
Installation instructions
For detecting the moving direction of the object, please pay attention to the installation direction of the sensor. The fastening torque should be below 0.8N m.
Setting method
Before setting up the instruction, confirm the light intensity mode or the color mode. The "COLOR" green indicator is always bright is color mode and extinguished as a color intensity mode.
Two point setting method
①When the projection light of the sensor against the measured color, presses the "ON" button, and the "GOOD" green indicator lights flicker.
②When the projection light of the sensor against the background color, presses the "OFF" button.
③When the threshold value set between steps ① and ② is stable, the "GOOD" green indicator light is always bright,vindicating that it can start normal detection. When the threshold value set between steps ① and ② is not stable, the "ERR" red indicator flashes for 3 seconds and revert to the last set state.
④If you want to switch NO (normally open) to NC (normally closed) output mode, you need to change the order of steps ① and ②.
Threshold value adjustment
①Press the "ON" button for more than 5 seconds until ERR, GOOD and COLOR three indicators flicker simultaneously.
②Press the "OFF" button to adjust the threshold value.
The relationship between the return difference state and the light flicker is as follows:
State | Indicator | Three indicator flicker |
Return difference value small | only the color indicator flicker | |
Return dirrerence value medium | GOOD、COLOR indicator flicker together | |
Return difference value large | ERR、GOOD、COLOR 3 indicator flicker together |
Exit threshold value adjustment
Under the condition of threshold adjustment, press the "ON" button for more than 5 seconds until the three lights of ERR, GOOD, and COLOR stop flashing, that is, the threshold return adjustment is withdrawn.
About false information hints
When error messages appear, please follow these methods.
Indicator light state | The "ERR" red indicator is always lit and will not be extinguished automatically. |
Error information content | The output line load is short circuited, and the overcurrent goes through. |
Handle | After turn off the power supply, check the output line load. |
Warning
• This product is only for target detection. Do not use this product to protect human body or body parts.
• This product shall not be used as an explosion-proof product. Do not use this product in hazardous or potential explosive gasenvironment.
• This product uses DC power supply, do not use AC power supply. If AC voltage is used, it may cause the product to explode or catch fire.